Aerosol & Powder Fire Extinguishers

Aerosol and Powder fire extinguisher technologies; By suppressing class A, B, C and E fires It can be used in many different application areas for the purpose of prevention.
In the light of the risk analysis evaluation results made by our competent engineers, land, sea and railway vehicles in motion, as well as buildings, facilities and strategic at important locations and equipment-station points, in open or closed environments Depending on variable detection scenarios or independently autonomous fire suppression solutions can be created.

Aerosol Fire Extinguishers

Aerosol fire suppression generators contain a pyrotechnic fill. The extinguishing agent in the form of a solid in the generator is an electrical or activated by thermal triggering methods. The chemical reaction that occurs as a result of triggering causes solid waste in the generator. The extinguishing agent does not pose a risk of fire in the event of a dense mist of potassium carbonate. It allows it to spread to the area where it occurs.

Powder Fire Extinguishers

Powder fire suppression reactors contain a non-pressurized powder extinguishing agent. Powder is 6 times higher than known dry chemical fire extinguishing powders (KKT). It has extinguishing power. The powder agent in the ISTO-1 standard is more diluted than known powders and is applied through a nano-process. As a result, its conductivity and adhesion properties were removed. Non-condensable and health hazard does not create. At the time of triggering, the high pressure created by the reaction of the solid chemical contained in the chamber by mobilizing the powder, it moves from the exit point of the generator to the targeted area. Allows spraying.

About

Aerosol Fire Extinguisher

Depending on the model and capacity characteristics of the aerosol generator, the risk of fire may The living environment is suppressed within 7 – 60 seconds. to the environment The emitted fog contains particle thicknesses ranging from 0.5μm to 1.5μm.
Aerosol fog affects fire in two ways;
• Physical Effect; It provides cooling by absorbing energy through ionization in the flame.
• Chemical Effect; Potassium carbonate emitted by aerosol fog contains oxygen other than By creating more radical compounds with free radicals, the fire continues.
It breaks the chain reaction required for Thus, combustion is interrupted
It ends by crashing. During this extinguishing, the oxygen in the environment is not suppressed and its amount is increased. There is no decrease that would hinder breathing. Aerosol fire extinguishing systems are environmentally friendly and safe, “GREEN” It is defined as “TECHNOLOGY”. The extinguishing agent has no harmful effects on any life form on Earth. It is not. It is a substance with non-toxic status.
“Eco-Friendly Replacement of HALON” by the American Environmental Protection Agency (EPA) It is listed as “Technology”.
• Aerosol fire extinguishing technique was introduced in the 2000s with ozone, which was used in fire extinguishing.
It was developed to replace gases that are harmful to human health.
• Highly engineered modern buildings, historical monuments, industrial facilities and equipment, tidy, fast and reliable fire extinguishing with minimum labor losses systems are provided.
• In case of fire, living creatures and valuable equipment can be saved by traditional extinguishing systems is protected much more effectively.
• Technology developed without human intervention, refilling, revision and It eliminates the possibility of malfunctions arising from application errors at the maximum level.
• The first moments between the outbreak of the fire and intervention determine the success in preventing the fire.
is the most important determining factor. Aerosol fire suppression technology, expressed in seconds The ability to break the combustion reaction in a short time, preventing losses provides great advantage.

About

Powder Fire Extinguisher

Cutting off contact with oxygen to cover the fire, covering the source and chemical reaction It extinguishes with a two-way function by breaking the combustion chain.  Another in other words; powder can cause fire on both surface (m2) and volume (m3) performs suppression.
Depending on the generator model and capacity, 35 meters outdoors. targeted up to distance extinguishing can be done. Powder generators ensure that the sealing condition is It is used effectively in open environments where it is not available.
Particularly in areas with limited access, such as cable galleries or raised floors It offers ideal solutions with its models that provide 360 ​​degree distribution. Transformer areas and It can be used quickly in areas with solvent-based fire risk thanks to its targeting feature provides suppression. It has a lifespan of 12 years. During its lifetime, filling, calibration, maintenance etc. It does not require.

General Application Areas

Electricity & Energy
• LV/MV Electricity Distribution Rooms
• Compensation Panels
• Cable Galleries
• Transformers and Generators
• Switch Cabinets
• Wind Turbines
• Power Plants
• Battery Charging Rooms

Information Technology and Communications
• Data Centers
• Server Rooms
• Base Stations
• Radio-TV Transmitters and Stations

Display & Storage
• Archives
• Warehouses
• Libraries
• Museums
• Buildings with Historical Artifact Status

Industry & Technology
• Production Lines
• CNC Machines
• Printing Machines
• Rolling mills
• Steel mills
• Flammable, Explosive Chemicals

Production and Storage Areas Transportation
• Highway Freight Vehicles
• Automobiles
• Road Public Transport Vehicles
• Railway Vehicles
• Ships, Yachts and Boats